Residential Electrical Panel Upgrade Checker

Residential Electrical Panel Upgrade Checker

Do I need an electrical panel upgrade? Checks whether your existing panel can take an EV charger, heat pump or induction range, using the real code load-calculation methods rather than a rule of thumb.

Your electrical panel

The number printed on the big switch at the top of the panel
A
Adoption is state by state — this changes the maths, not just the wording
V
Advanced / Custom Input — my panel
Overrides the amps above. Leave at 0 to use the breaker rating.
kVA
Some authorities want a margin left unused.
%

About the home

Heated living space — skip the garage, porch and unfinished basement
sq ft
The code requires at least two
nos
nos
Roughly how many light fittings in the house
nos
nos
Add up the fittings, or leave the estimate
W
32 A ring finals
nos
20 A radial finals
nos
No diversity is allowed on this — it counts in full
kW
Advanced / Custom Input — about the home
From a survey or an earlier calculation. Replaces the area and circuit maths.
kVA

What you already have

These start at typical values. Change any that do not match, or set one to 0 if you do not have it.

The cooker, not a separate cooktop
kW
Leave at 0 for a gas dryer
kW
Tank or tankless — use the nameplate
kW
kW
kW
Only if it is wired in, not plugged in
kW
kW
Running watts from the nameplate
kW
Baseboards or a furnace heat strip
kW
Advanced / Custom Input — existing loads
Replaces every appliance figure above. Leave at 0 to add them up one by one.
kW

What you want to add

The circuit breaker size the charger needs
A
nos
Running watts of the outdoor unit
kW
The electric element that helps on cold days
kW
kW
Advanced / Custom Input — new loads
Counted in full, on top of the charger and heat pump above.
kW

Load management

It throttles the charger when the house is busy, instead of upgrading the panel
A
Advanced / Custom Input — load management
A whole-site limiter rather than a charger-only throttle. Leave at 0 if it only controls the charger.
kW
Advanced / Custom Input — override any assumption

The metered method — NEC 220.87

If you can get your highest demand over the last 12 months from the utility or a smart meter, this is the most accurate method there is — and it usually gives far more headroom than a calculation from scratch. Leave it at 0 to skip it.

kW
%

NEC demand factors

VA/ft²
VA
%
VA
kW
VA
%
%
%

Canadian Electrical Code — CSA C22.1 Section 8

W
W
W
W
W
%
%
%

Germany — DIN 18015-1 Annex A

VA
VA
%
%

General IEC estimate — conservative allowances

This country’s own diversity table is not encoded yet, so these deliberately cautious allowances are used instead. They will tend to over-estimate. Change any of them if you know your local figures.

%
%
%
%

BS 7671 diversity — IET On-Site Guide Appendix A

%
%
A
%
A
A
%

AS/NZS 3000 Appendix C — Table C1 column 2

A
A
A
A
%
%
%

Your own parameter

Anything the fields above do not cover — a workshop sub-feed, a hot tub, a grow tent, a second kitchen. Positive adds load; negative removes it.

Result

Fill in your panel and loads, then press “Check my panel”.

Estimate only — verify with a licensed electrician/engineer and your local code authority before final installation.